中文
Announcement
More
Progress in Chemistry 2006, Vol. 18 Issue (04): 494-500 Previous Articles   Next Articles

• Review •

The Conception, Structure and Techniques on the ArtificialIntelligent Taste System

Ganhui Huang 1,2 ;Shaoping Deng2**   

  1. 1.Key Laboratory of Food Science of MOE, Nanchang University,Nanchang 330047, China; 2.Sensory Science Laboratory, Zhejiang Gongshang University, Hangzhou 310035, China
  • Received: Revised: Online: Published:
  • Contact:

    Shaoping Deng

PDF ( 1904 ) Cited
Export

EndNote

Ris

BibTeX

The traditional taste sensor, artificial taste and electronic tongue are taken into consideration as a whole of the artificial intelligent taste system (AITS) and thus the related concepts, structure and techniques of the system are proposed. In the traditional transducer analytics, the non-specific selection is a defect phenomenon which should be avoided as far as possible. However, it serves as the fundament of the cross-sensitive sensors array which is designed and constructed as an optimal sensor compose to enable the realization of the AITS. Consequently, the cross-sensitive theory and techniques are the core concepts of the AITS. As a bionic sense technique, the AITS is composed of three parts, namely the cross-sensitive sensors and their array, self-study specialist database and intelligent recognition. The voltammetric and the potentiometric techniques are two main test methods. The sensitive materials include noble metals, rare earth metals, lipids and lipids polymer, chalcogenide glass materials, conductive polymers and other materials such as graphite paste, phthalocyanin, Prussia blue etc. The PCA and the ANN are the primary pattern recognition tools in intelligent recognition. The sensors modified by conductive polymer and the multi-technique integrated methods are two important research fields in the artificial intelligent taste system.

CLC Number: 

[ 1 ] Li R , Wang P , Hu W L. Sensors and Actuators B , 2000 , 66 :246 —250
[ 2 ] 滕炯华(Teng J H) , 王磊(Wang L) , 袁朝辉(Yuan Z H) . 测控技术(Measurement & Control Technology) , 2004 , 23 (11) :4 —5
[ 3 ] Esbensen K, Kirsanov D , Legin A , et al . Anal . Bioanal .Chem. , 2004 , 378 : 391 —395
[ 4 ] Legin A , Kirsanov D , Rudnitskaya A , et al . Talanta , 2004 , 64 :766 —772
[ 5 ] Turner C , Rudnitskaya A , Legin A. Journal of Biotechnology ,2003 , 103 : 87 —91
[ 6 ] Legin A , Rudnitskaya A , Vlasov Y, et al . Sensors and Actuators B , 1997 , 44 : 291 —296
[ 7 ] Legin A , Rudnitskaya A , Vlasov Y, et al . Sensors and Actuators B , 2000 , 65 : 232 —234
[ 8 ] Toko K. Biosensors &Bioelectronics , 1998 , 13 : 701 —709
[ 9 ] Rudnitskaya A , Ehlert A , Legin A , et al . Talanta , 2001 , 55 :425 —431
[10] Legin A , Rudnitskaya A , Lvova L , et al . Analytica Chimica Acta , 2003 , 484 : 33 —44
[11] Toko K. Sensors and Actuators B , 2000 , 64 : 205 —215
[12] Ramón M M, Juan S , Eduardo G B , et al . Sensors and Actuators B , 2005 , 104 : 302 —307
[13] Corrado D N , Roberto P , Antonella M, et al . Sensors and Actuators B , 2000 , 64 : 15 —21
[14] Vlasov Y G, Legin A V , Rudnitskaya A M, et al . Sensors and Actuators B , 2000 , 65 : 235 —236
[15] Ivarsson P , Kikkawa Y, Winquist F , et al . Analytica Chimica Acta , 2001 , 449 : 59 —68
[16] Szpakowska M, Szwacki J , Lisowska2Oleksiak A , et al .Desalination , 2004 , 163 : 55 —59
[17] Schêning M J , Schmidt C , Schubert J , et al . Sensors and Actuators B , 2000 , 68 : 254 —259
[18] Mourzina Y G, Schubert J , Zander W, et al . Electrochimica Acta , 2001 , 47 : 251 —258
[19] Lvova L , Legin A , Vlasov Y, et al . Sensors and Actuators B ,2003 , 95 : 391 —399
[20] Arrieta A A , Apetrei C , Rodrìguze-Méndez M L , et al .Electrochimica Acta , 2004 , 49 : 4543 —4551
[21] Lvova L , Kim S S , Legin A , et al . Analytica Chimica Acta ,2002 , 468 : 303 —314
[22] Parra V , Hernando T, Rodriguez-Méndez M L , et al .Electrochimica Acta , 2004 , 49 : 5177 —5185
[23] Legin A , Makarychev-Mikhailov S , Goryacheva O , et al .Analytica Chimica Acta , 2002 , 457 : 297 —303
[24] Legin A , Makarychev-Mikhailov S , Kirsanov D , et al . Analytica Chimica Acta , 2004 , 514 : 107 —113
[25] Nguyen T A , Daniela S K, Ongarato M, et al . Electroanalysis ,1999 , 18 (11) : 1327 —1332
[26] 董绍俊(Dong S J ) , 车广礼(Che G L) , 谢远武(Xie Y W) . 化学修饰电极(Chemically Modified Electrodes) . 北京:科学出版社(Beijing : Science Press) ,1995. 32 —39
[27] Buehler M G, Kuhlman GM, Keymeulen D. Advanced Electronic Tongue Concept , 2002 IEEE Aerospace Conference. USA Montana , 2002. 407 —416
[28] Arrieta A , Rodriguez-Mendez M L , de Saja J A. Sensors and Actuators B , 2003 , 95 : 357 —365
[29] Krantz-Rülcker C , Stenberg M, Winquist F , et al . Analytica Chimica Acta , 2001 , 426 : 217 —226
[30] Schêning M J , Schmidt C , Schubert J , et al . Sensors and Actuators B , 2000 , 68 : 254 —259
[31] Schêning M J , Mourzina Y G, Schubert J , et al . Sensors and Actuator B , 2001 , 78 : 273 —278
[32] Ivarsson P , Holmin S , Hê jer N E , et al . Sensors and Actuators B , 2001 , 76 : 449 —454
[33] Holmin S , Sp? ngeus P , Krantz-Rülcker C , et al . Sensors and Actuator B , 2001 , 76 : 455 —464
[34] Winquist F , Holmin S , Krantz-Rülcker C , et al . Analytica Chimica Acta , 2000 , 406 : 147 —157
[35] Riul A J , Malmegrim R R , Fonseca F J , et al . Biosensors and Bioelectronics , 2003 , 18 : 1365 —1369
[36] Buratti S , Benedetti S , Scampicchio M, et al . Analytica Chimica Acta , 2004 , 525 : 133 —139
[37] Sehra G, Cole M, Gardner J W, et al . Sensors and Actuators B ,2004 , 103 : 233 —239
[38] OpSullivan C K, Guilbault G G. Biosensors & Bioelectronics ,1999 , 14 : 663 —670
[39] Artursson T, Holmberg M. Sensors and Actuators B , 2002 , 87 :379 —391
[40] Riul A J , de Sousa H C , Malmegrim R R , et al . Sensors and Actuators B , 2004 , 98 : 77 —82
[41] Kish L B , Vajtai R , Granqvist C G. Sensors and Actuators B ,2000 , 71 : 55 —59
[42] Artursson T, Sp? ngeus P , HolmbergM. Analytica Chimicaa Acta ,2002 , 452 : 255 —264
[43] Winquist F , Rydberg E , Holmin S , et al . Analytica Chimica Acta , 2002 , 471 : 159 —172
[44] Mortensen J , Legin A , Ipatov A , et al . Analytica Chimica Acta ,2000 , 403 : 273 —277
[45] Ipatov A , Ivanov M, Makarychev-Mikhailov S , et al . Talanta ,2002 , 58 : 1071 —1076
[46] Gallardo J , Alegret S , del Valle M. Sensors and Actuators B ,2004 , 101 : 72 —80
[47] Winquist F , Lundstrêm I , Wide P. Sensors and Actuators B ,1999 , 58 : 512 —517
[48] Bleibaum R N , Stone H , Tan T, et al . Food Quality and Preference , 2002 , 6 : 409 —422
[49] Di Natale C , Paolesse R , Burgio M, et al . Analytica Chimica Acta , 2004 , 513 : 49 —56
[50] Ciosek P , Brzózka Z, Wróblewski W. Sensors and Actuators B ,2004 , 103 : 76 —83

[1] Zhaoying Pan, Jianzhong Ma, Wenbo Zhang, Linfeng Wei. Flexible Conductive Polymer Composites in Strain Sensors* [J]. Progress in Chemistry, 2020, 32(10): 1592-1607.
[2] Gu Lin, Ding Jiheng, Yu Haibin. Research in Graphene-Based Anticorrosion Coatings [J]. Progress in Chemistry, 2016, 28(5): 737-743.
[3] Yang Lei, Cheng Tao, Zeng Wenjin, Lai Wenyong, Huang Wei. Inkjet-Printed Conductive Polymer Films for Optoelectronic Devices [J]. Progress in Chemistry, 2015, 27(11): 1615-1627.
[4] Shao Liang, Liu Mingzhu, Qiu Jianhui, Gao Chunmei, Zhang Guohong, Qin Lijun. Preparation of Conductive Hydrogel [J]. Progress in Chemistry, 2011, 23(5): 923-929.
[5] Cui Mengzhong1,2,Li Zhuyun2,Yuan Weizhong1,Xi Jingyu1,Zhu Lu1,Tang Xiaozhen1*. Progress in Organic Polysilanes Interrupted by Oxygen [J]. Progress in Chemistry, 2005, 17(05): 860-867.