English
新闻公告
More
化学进展 2007, Vol. 19 Issue (11): 1820-1825 前一篇   后一篇

• 综述与评论 •

手性传感器研究进展*

翁文1** 韩景立1 陈友遵1 黄晓佳2   

  1. (1. 漳州师范学院化学与环境科学系 漳州 363000;2. 厦门大学海洋与环境学院 厦门 361005)
  • 收稿日期:2006-12-30 修回日期:2007-05-01 出版日期:2007-11-14 发布日期:2007-11-25
  • 通讯作者: 翁文

Progress in Chiral Sensors

Weng Wen1** Han Jingli1 Chen Youzun1 Huang Xiaojia2   

  1. (1.Department of Chemistry and Environmental Science, Zhangzhou Normal University, Zhangzhou 363000, China; 2. College of Oceanography and Environmental Science, Xiamen University, Xiamen 361005, China)
  • Received:2006-12-30 Revised:2007-05-01 Online:2007-11-14 Published:2007-11-25
  • Contact: Weng Wen
手性工程的崛起对简单、经济、快速、实时、在线的手性检测技术提出了挑战。手性传感器是一个重要的发展趋势。本文综述了近年来在手性电化学传感器、基于石英晶体微天平的手性质量化学传感器及手性光学传感器方面的研究进展,重点介绍了各种传感器的制备及其在手性检测中的应用,并展望了该领域的发展前景。
The development of chiral project requires chiral analytical technologies with simple handle, low cost, high speed, real time and on-line operation. Chiral sensor system represents a major branch of future research. In this paper, the progresses in chiral electrochemical sensor, chiral mass chemical sensor based on quartz crystal microbalance and chiral optical sensor were reviewed. The preparations and applications of these chiral sensors were introduced. The prospects of this field were also put forward.

中图分类号: 

()

[ 1 ] Maier N M, Franco P , Lindner W. J . Chromatogr. A , 2001 ,906 : 3 —33
[ 2 ] Pu L. Chem. Rev. , 2004 , 104 : 1687 —1716
[ 3 ] Ghosh K, Adhikari S. Tetrahedron Lett . , 2006 , 47 : 3577 —3581
[ 4 ] Zhao J Z, Davidson M G, Mahon M F , et al . J . Am. Chem.Soc. , 2004 , 126 : 16179 —16186
[ 5 ] Xu K X, He Y B , Qin H J , et al . Tetrahedron : Asymmetry ,2005 , 16 : 3042 —3048
[ 6 ] 文孟良(Wen M L) , 赵益斌(Zhao Y B) , 王昌益(Wang C Y) .云南化工(Yunnan Chem. Tech. ) , 1997 , (2) : 5 —10
[ 7 ] Yasaka Y, Yamamoto T, Kimura K, et al . Chem. Lett . , 1980 ,9 : 769 —772
[ 8 ] Bussmann W, Lehn J M, Oesch U , et al . Helv. Chem. Acta ,1981 , 64 : 657 —661
[ 9 ] Bates P S , Kataky R , Parker D. J . Chem. Soc. Chem.Commun. , 1992 , 153 —155
[10] Horváth V , Takács T, Horvai G, et al . Anal . Lett . , 1997 , 30 :1591 —1609
[11] Stefan R I , van Staden J F , Aboul-Enein H Y. Cryst . Eng. ,2001 , 4 : 113 —118
[12] Ozoemena K I , Stefan R I , Staden J F , et al . Sensor. Actuat . B ,2005 , 105 : 425 —429
[13] Stefan R I , van Staden J F , Aboul-Enein H Y. Chirality , 1999 ,11 : 631 —634
[14] Stefan R I , van Stad en J F , Aboul-Enein H Y. Electroanal . ,1999 , 11 : 192 —194
[15] Aboul-Enein H Y, Stefan R I , van Staden J F. Anal . Lett . ,1999 , 32 : 623 —632
[16] Stefan R I , van Staden J F , Aboul-Enein H Y. Anal . Lett . ,1998 , 31 : 1787 —1794
[17] Stefan R I , van Staden J F , Aboul-Enein H Y. Talanta , 1999 ,48 : 1139 —1143
[18] Ozoemena K I , Stefan R I. Sensor. Actuat . B , 2004 , 98 : 97 —100
[19] Stefan R I , van Staden J F , Aboul-Enein H Y. Fresenius J .Anal . Chem. , 2001 , 370 : 33 —37
[20] Yin X L , Ding J J , Zhang S , et al . Biosens. Bioelectron. , 2006 ,21 : 2184 —2187
[21] Wang Y X, Yin X L , Shi M H , et al . Talanta , 2006 , 69 :1240 —1245
[22] Van Staden J F , Stefan R I , Aboul-Enein H Y. Fresenius J .Anal . Chem. , 2000 , 367 : 178 —180
[23] Stefan R I , van Staden J F , Aboul-Enein H Y. Sensor. Actuat .B , 1999 , 54 : 261 —265
[24] Stefan R I , van Staden J F , Aboul-Enein H Y. Electroanal . ,1999 , 11 : 1233 —1235
[25] Stefan R I , van Staden J F , Aboul-Enein H Y. Talanta , 2000 ,51 : 969 —975
[26] Gavalas V G, Law S A , Ball J C , et al . Anal . Biochem. , 2004 ,329 : 247 —252
[27] Kwan R C H , Hon P Y T, Renneberg R. Anal . Chim. Acta ,2004 , 523 : 81 —88
[28] Wcislo M, Compagnone D , Trojanowicz M. Bioelectrochem. ,2006 , 71 : 223 —230
[29] Aboul-Enein H Y, Stefan R I , Radu G L , et al . Anal . Lett . ,1999 , 32 : 447 —455
[30] Severin E J , Sanner R D , Doleman B J , et al . Anal . Chem. ,1998 , 70 : 1440 —1443
[31] May I P , Byfield M P , Lindstrêm M, et al . Chirality , 1997 , 9 :225 —232
[32] Fietzek C , Hermle T, Rosenstiel W, et al . Fresenius J . Anal .Chem. , 2001 , 371 : 58 —63
[33] Bodenhêfer K, Hierlemann A , Juza M, et al . Anal . Chem. ,1997 , 69 : 4017 —4031
[34] Hierlemann A , Ricco A J , Bodenhêfer K, et al . Anal . Chem. ,1999 , 71 : 3022 —3035
[35] Guo W, Wang J , Wang C , et al . Tetrahedron Lett . , 2002 , 43 :5665 —5667
[36] Tanese M C , Torsi L , Cioffi N , et al . Sensor. Actuat . B , 2004 ,100 : 17 —21
[37] Ng S C , Sun T, Chan H S O. Tetrahedron Lett . , 2002 , 43 :2863 —2866
[38] Kempe M, Mosbach K. J . Chromatogr. A , 1995 , 694 : 3 —13
[39] Haupt K, Noworyta K, Kutner W. Anal . Commun. , 1999 , 36 :391 —393
[40] Cao L , Zhou X C , Li S F Y. Analyst , 2001 , 126 : 184 —188
[41] Piacham T, Josell A , Arwin H , et al . Anal . Chim. Acta , 2005 ,536 : 191 —196
[42] Liao H P , Zhang Z H , Nie L H , et al . J . Biochem. Biophys.Methods , 2004 , 59 : 75 —87
[43] 王军军(Wang J J ) , 谢海芬(Xie H F) , 周嘉(Zhou J ) 等. 微电子学(Microelectro. ) , 2004 , 34 : 493 —496
[44] 黄钦文(Huang X W) , 陈大鹏(Chen D P) , 叶甜春( Ye T C)等. 电子工业专用设备( Equipment for Electronic Products Manufacturing) , 2006 , 132 : 36 —38
[45] Dutta P , Tipple C A , Lavrik N V , et al . Anal . Chem. , 2003 ,75 : 2342 —2348
[46] Yoshikawa M, Hotta N , Kyoumura J , et al . Sensors Actuat . B ,2005 , 104 : 282 —288
[47] Hofstetter O , Hofstetter H , Wilchek M, et al . Nature Biotech. ,1999 , 17 : 371 —374
[48] Nopper D , Lammershop O , Wulff G, et al . Anal . Bioanal .Chem. , 2003 , 377 : 608 —613
[49] Bodenhêfer K, Hierlemann A , Seemann J , et al . Anal . Chem. ,1997 , 69 : 3058 —3068
[50] Bodenhêfer K, Hierlemann A , Seemann J , et al . Nature , 1997 ,387 : 577 —580
[51] Kieser B , Fietzek C , Schmidt R , et al . Anal . Chem. , 2002 ,74 : 3005 —3012
[52] Hofstetter H , Hofstetter O. Trends in Anal . Chem. , 2005 , 24(10) : 869 —879
[53] Schügerl K, Ulber R , Scheper T. Trends in Anal . Chem. , 1996 ,15 : 56 —62

[1] 钟衍裕, 王正运, 刘宏芳. 抗坏血酸电化学传感研究进展[J]. 化学进展, 2023, 35(2): 219-232.
[2] 孙义民, 李厚燊, 陈振宇, 王东, 王展鹏, 肖菲. MXene在电化学传感器中的应用[J]. 化学进展, 2022, 34(2): 259-271.
[3] 罗钧, 郑炎松. 手性杯芳烃及其超分子手性[J]. 化学进展, 2018, 30(5): 601-615.
[4] 姜信欣, 赵成军, 钟春菊, 李建平*. MOF构筑的电化学传感器及应用[J]. 化学进展, 2017, 29(10): 1206-1214.
[5] 龚德君, 高冠斌, 张明曦, 孙涛垒. 手性金团簇的制备、性质及应用[J]. 化学进展, 2016, 28(2/3): 296-307.
[6] 邢立文, 马占芳. 基于碳纳米材料的无酶电化学传感器同时检测抗坏血酸、多巴胺和尿酸[J]. 化学进展, 2016, 28(11): 1705-1711.
[7] 李敏睿, 郭永亮, 杨保平, 郭军红, 崔锦峰. 基于脲衍生物阴离子识别的电化学检测[J]. 化学进展, 2015, 27(5): 559-570.
[8] 王振强, 杨明庆, 贺军辉, 杨巧文. 不同种类敏感膜修饰的QCM气体传感器研究现状[J]. 化学进展, 2015, 27(2/3): 251-266.
[9] 靳清贤, 李晶, 李孝刚, 张莉, 方少明, 刘鸣华. 超分子凝胶的手性功能应用:手性分子识别与不对称催化[J]. 化学进展, 2014, 26(06): 919-930.
[10] 孙兵, 艾仕云. 光电化学传感器的构建及应用[J]. 化学进展, 2014, 26(05): 834-845.
[11] 武金丹, 巨勇. 基于天然产物骨架的分子离子识别体系[J]. 化学进展, 2013, 25(11): 1888-1897.
[12] 尉艳, 刘中刚, 高超, 王伦, 刘锦淮, 黄行九. 纳米材料电化学与生物传感器--有机微污染物检测新途径[J]. 化学进展, 2012, 24(04): 616-627.
[13] 安众福 陈润锋 史慧芳 马琮 石乃恩 黄维. 联萘酚衍生物的光电功能及其应用*[J]. 化学进展, 2010, 22(10): 1973-1982.
[14] 杨海朋,陈仕国,李春辉,陈东成,戈早川. 纳米电化学生物传感器*[J]. 化学进展, 2009, 21(01): 210-216.
[15] 卿光焱,刘顺英,何永炳. 基于杯[4]芳烃的手性识别*[J]. 化学进展, 2008, 20(12): 1933-1944.
阅读次数
全文


摘要

手性传感器研究进展*